2.Medical handle spot size 1-10mm ,10-20mm adjustable face & body hair removal solution!
Top Supplier 755Nm / 1064Nm Yag Alexandrite Laser Machine For Hair Removal
Model EL200B Pulse Width Adjustable Nd:YAG/ALEX laser therapy instrument
the working wavelength of EL200B is 1064 nm &755 nm.
Professional hair removal, currently the world's high-quality hair removal technology. It can treat onychomycosis and varicose veins.
the working wavelength of EL200B is 1064 nm &755 nm.
Advantage
♦Wavelength of 1064nm and 755nm Nd:YAG laser is a kind of invisible light, in this
case, visible light is adopted to scan the deased tissue first, the area of visible light
is the target of Nd:YAG laser emission. This instrument choose red diode laser as the
aiming beam.
Theory
♦Elimination of unwanted hair by the means of the alexandrite laser is based on the mechanism of the thermokinetic selectivity, minimising the sensation of pain and any side effect. The laser emits a beam invisible to the human eye that penetrates in depth the skin without causing any damage. Only the hair follicle absorbs selectively the laser Ray, and through a process of intense heating at very high temperatures is caused the denaturation of the roots and the surrounding germinative cells that are
responsible for the re-growth. The result is the permanent and progressive elimination of the hair without provoking any particular irritation or the insult of the skin.
responsible for the re-growth. The result is the permanent and progressive elimination of the hair without provoking any particular irritation or the insult of the skin.
Parameter setting method
1),Energy setting:The setting is for every single pulse energy, when the wavelength is 1064nm,energy can be adjusted between 0.1~80J. When it is 755nm, energy is between 0.7~30J. Under “stand by” and “ready” condition, one can set the energy.
2),Frequency setting: when the wavelength is 1064nm, frequency can be adjusted between 0.1~50Hz, when the wavelength is 755nm, the frequency can be adjusted between 0.5~20Hz. One can set the frequency under both ready and standby condition
3),Wavelength selection:when the wavelength is 1064nm,the wavelength can be adjusted between 0.1~200ms,when it is 755nm,the wavelength can be adjusted between0.5~20
2),Frequency setting: when the wavelength is 1064nm, frequency can be adjusted between 0.1~50Hz, when the wavelength is 755nm, the frequency can be adjusted between 0.5~20Hz. One can set the frequency under both ready and standby condition
3),Wavelength selection:when the wavelength is 1064nm,the wavelength can be adjusted between 0.1~200ms,when it is 755nm,the wavelength can be adjusted between0.5~20